• Operating Pressure: 690 bar (10,000 PSI)
• Equivalent Depth: 6900 metres or 22,500 feet below sea level
• Temperature: 20°C to +100°C
• Chamber Size: Vessel bore Ø500mm x 2500mm depth (1.6ft x 8.2ft)
• Test Media: Water / Water & Glycol
• Closure: Semi-quick acting with multiple ports & test product handling system
• Fully enclosed cell with safety interlock door for safe & reliable access
• Full test reports & camera system for operational use
Pressure Control System Specification and Functionality
• Fully Automated Pressure Control System
• Pressurising / Depressurisation (Venting)
• Pressure Maintain Mode
• Leak Test Mode
• Cyclic Pressure Loops
• Profiling
Maximum Operating: 690 Bar (10,000 PSI)
Pressurisation Control Rates: Linear between 10 and 50 Bar/ min
Pressurization Ramp Tolerance to be maintained within +/- 10% (of full scale)
Depressurisation Control Rates: Linear between 10 and 50 Bar/ min
Depressurisation Ramp Tolerance to be maintained within +/- 10% (full scale)
Dwell Period: 1 mins to 3 months
Dwell Period Pressure stability: 0 (zero) Bar to +5 Bar